We locate and eliminate the moisture supply feeding the mold using FLIR thermal cameras and digital moisture meters.
2. Negative-Pressure Containment Chamber
We build sealed 6-mil poly containment chambers with HEPA-filtered air scrubbers exhausting outside to prevent cross-contamination into living areas.
3. Controlled Demolition & HEPA Vacuuming
Contaminated drywall and porous materials are removed under negative pressure, followed by HEPA vacuuming and wire-brushing of structural framing.
4. EPA Fungicidal Coating & Third-Party Clearance
Exposed wood is sealed with EPA-registered antimicrobial fungicidal coatings, followed by mandatory independent third-party laboratory air clearance testing.
Specialized Equipment We Deploy
HEPA 500 Industrial Air Scrubbers
6-Mil Flame-Retardant Poly Containment
EPA-Registered Fungicidal Coatings
Non-Invasive Moisture Detectors
Service Questions & Answers
Why shouldn’t I spray bleach on mold on drywall?+
Bleach is 90% water and cannot penetrate porous materials like drywall and wood. The chlorine evaporates quickly on the surface, while the remaining water soaks in and feeds the microscopic mold hyphae (roots), making the colony grow back stronger.
How do you prove the mold is completely gone?+
We require an independent, third-party certified indoor environmental hygienist (IEH) to conduct air and surface spore sampling before taking down containment, issuing an official Certificate of Clearance.